Publications
Imagerie cardiovasculaire
- Replacing Vascular Corrosion Casting by In Vivo Micro-CT Imaging for Building 3D Cardiovascular Models in Mice
Vandeghinste B, Trachet B, Renard M, Casteleyn C, Staelens S, Loeys B, Segers P, Vandenberghe S.
Mol Imaging Biol. 2011 Feb;13(1):78-86.PMID: 20449667 [PubMed - in process] - Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray
Cao G, Burk LM, Lee YZ, Calderon-Colon X, Sultana S, Lu J, Zhou O.
Med Phys. 2010 Oct;37(10):5306-12 - Fully automated intrinsic respiratory and cardiac gating for small animal CT
Kuntz J, Dinkel J, Zwick S, Bäuerle T, Grasruck M, Kiessling F, Gupta R, Semmler W, Bartling SH.
Phys Med Biol. 2010 Apr 7;55(7):2069-85. Epub 2010 Mar 19.PMID: 20299735 [PubMed - indexed for MEDLINE] - A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source
Cao G, Lee YZ, Peng R, Liu Z, Rajaram R, Calderon-Colon X, An L, Wang P, Phan T, Sultana S, Lalush DS, Lu JP, Zhou O.
Phys Med Biol. 2009 Apr 21;54(8):2323-40. Epub 2009 Mar 25.PMID: 19321922 [PubMed - indexed for MEDLINE] - Intrinsic gating for small-animal computed tomography: a robust ECG-less paradigm for deriving cardiac phase information and functional imaging
Dinkel J, Bartling SH, Kuntz J, Grasruck M, Kopp-Schneider A, Iwasaki M, Dimmeler S, Gupta R, Semmler W, Kauczor HU, Kiessling F.
Circ Cardiovasc Imaging. 2008 Nov;1(3):235-43 - Longitudinal follow-up of cardiac structure and functional changes in an infarct mouse model using retrospectively gated micro-computed tomography
Detombe SA, Ford NL, Xiang F, Lu X, Feng Q, Drangova M.
Invest Radiol. 2008 Jul;43(7):520-9.PMID: 18580335 [PubMed - indexed for MEDLINE] - Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT
Song J, Liu QH, Johnson GA, Badea CT.
Med Phys. 2007 Nov;34(11):4476-83.PMID: 18072512 [PubMed - indexed for MEDLINE] - Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice
Drangova M, Ford NL, Detombe SA, Wheatley AR, Holdsworth DW.
Invest Radiol. 2007 Feb;42(2):85-94.PMID: 17220726 [PubMed - indexed for MEDLINE] - Retrospective motion gating in small animal CT of mice and rats
Bartling SH, Stiller W, Grasruck M, Schmidt B, Peschke P, Semmler W, Kiessling F.
Invest Radiol. 2007 Oct;42(10):704-14.PMID: 17984768 [PubMed - indexed for MEDLINE] - Cardiac micro-computed tomography for morphological and functional phenotyping of muscle LIM protein null mice
Badea CT, Hedlund LW, Mackel JF, Mao L, Rockman HA, Johnson GA.
Mol Imaging. 2007 Jul-Aug;6(4):261-8.PMID: 17711781 [PubMed - indexed for MEDLINE] - Imaging methods for morphological and functional phenotyping of the rodent heart
Badea CT, Bucholz E, Hedlund LW, Rockman HA, Johnson GA.
Toxicol Pathol. 2006;34(1):111-7.PMID: 16507552 [PubMed - indexed for MEDLINE] - 4-D micro-CT of the mouse heart
Badea CT, Fubara B, Hedlund LW, Johnson GA.
Mol Imaging. 2005 Apr-Jun;4(2):110-6.PMID: 16105509 [PubMed - indexed for MEDLINE] - Practical vessel imaging by computed tomography in live transgenic mouse models for human tumors
Kindlmann GL, Weinstein DM, Jones GM, Johnson CR, Capecchi MR, Keller C.
Mol Imaging. 2005 Oct-Dec;4(4):417-24.PMID: 16285903 [PubMed - indexed for MEDLINE]
Si vous voulez ajouter votre publication à cette liste de référence, contactez-nous à .
Oncologie
Métastase de foie
- In vivo micro-CT imaging of liver lesions in small animal models
Martiniova L, Schimel D, Lai EW, Limpuangthip A, Kvetnansky R, Pacak K.
Methods. 2010 Jan;50(1):20-5. Epub 2009 Jun 9. Review - Noninvasive monitoring of a murine model of metastatic pheochromocytoma: a comparison of contrast-enhanced microCT and nonenhanced MRI
Martiniova L, Kotys MS, Thomasson D, Schimel D, Lai EW, Bernardo M, Merino MJ, Powers JF, Ruzicka J, Kvetnansky R, Choyke PL, Pacak K.
J Magn Reson Imaging. 2009 Mar;29(3):685-91 - Contrast-enhanced microcomputed tomography using intraperitoneal contrast injection for the assessment of tumor-burden in liver metastasis models
Graham KC, Detombe SA, MacKenzie LT, Holdsworth DW, MacDonald IC, Chambers AF, Drangova M.
Invest Radiol. 2008 Jul;43(7):488-95.PMID: 18580331 [PubMed - indexed for MEDLINE] - Micro-CT imaging with a hepatocyte-selective contrast agent for detecting liver metastasis in living mice
Kim HW, Cai QY, Jun HY, Chon KS, Park SH, Byun SJ, Lee MS, Oh JM, Kim HS, Yoon KH.
Acad Radiol. 2008 Oct;15(10):1282-90.PMID: 18790400 [PubMed - indexed for MEDLINE] - Noninvasive quantification of tumor volume in preclinical liver metastasis models using contrast-enhanced x-ray computed tomography
Graham KC, Ford NL, MacKenzie LT, Postenka CO, Groom AC, MacDonald IC, Holdsworth DW, Drangova M, Chambers AF.
Invest Radiol. 2008 Feb;43(2):92-9.PMID: 18197061 [PubMed - indexed for MEDLINE] - In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice
Almajdub M, Nejjari M, Poncet G, Magnier L, Chereul E, Roche C, Janier M.
Contrast Media Mol Imaging. 2007 Mar;2(2):88-93.PMID: 17444558 [PubMed - indexed for MEDLINE] - MicroCT for high-resolution imaging of ectopic pheochromocytoma tumors in the liver of nude mice
Ohta S, Lai EW, Morris JC, Bakan DA, Klaunberg B, Cleary S, Powers JF, Tischler AS, Abu-Asab M, Schimel D, Pacak K.
Int J Cancer. 2006 Nov 1;119(9):2236-41.PMID: 16841334 [PubMed - indexed for MEDLINE]
Tumeur de rate
- In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice
Almajdub M, Nejjari M, Poncet G, Magnier L, Chereul E, Roche C, Janier M.
Contrast Media Mol Imaging. 2007 Mar;2(2):88-93.PMID: 17444558 [PubMed - indexed for MEDLINE]
Cancer ovarien
- Visualization and quantification of intraperitoneal tumors by in vivo computed tomography using negative contrast enhancement strategy in a mouse model of ovarian cancer
Rampurwala M, Ravoori MK, Wei W, Johnson VE, Vikram R, Kundra V.
Transl Oncol. 2009 May;2(2):96-106.PMID: 19412425 [PubMed - in process]
Cancer du colon
- Targeting FGF19 inhibits tumor growth in colon cancer xenograft and FGF19 transgenic hepatocellular carcinoma models
Desnoyers LR, Pai R, Ferrando RE, Hötzel K, Le T, Ross J, Carano R, D'Souza A, Qing J, Mohtashemi I, Ashkenazi A, French DM.
Oncogene. 2008 Jan 3;27(1):85-97. Epub 2007 Jun 25.PMID: 17599042 [PubMed - indexed for MEDLINE]
Amyloïde de chaîne légère
- Radioimaging of light chain amyloid with a fibril-reactive monoclonal antibody
Wall JS, Kennel SJ, Paulus M, Gregor J, Richey T, Avenell J, Yap J, Townsend D, Weiss DT, Solomon A.
J Nucl Med. 2006 Dec;47(12):2016-24.PMID: 17138745 [PubMed - indexed for MEDLINE]
Métastase de poumon
- Visualization of experimental lung and bone metastases in live nude mice by X-ray micro-computed tomography
Li XF, Zanzonico P, Ling CC, O'Donoghue J.
Technol Cancer Res Treat. 2006 Apr;5(2):147-55.PMID: 16551134 [PubMed - indexed for MEDLINE]
Réseau vasculaire dans la tumeur
- Practical vessel imaging by computed tomography in live transgenic mouse models for human tumors
Kindlmann GL, Weinstein DM, Jones GM, Johnson CR, Capecchi MR, Keller C.
Mol Imaging. 2005 Oct-Dec;4(4):417-24.PMID: 16285903 [PubMed - indexed for MEDLINE]
Si vous voulez ajouter votre publication à cette liste de référence, contactez-nous à .
Imagerie de foie et de rate et reconstruction 3D
- An anatomical mouse model for multimodal molecular imaging
Zhang X, Tian J, Feng J, Zhu S, Yan G.
Conf Proc IEEE Eng Med Biol Soc. 2009;2009:5817-20 - Time-course of contrast enhancement in spleen and liver with Exia 160, Fenestra LC, and VC
Willekens I, Lahoutte T, Buls N, Vanhove C, Deklerck R, Bossuyt A, de Mey J.
Mol Imaging Biol. 2009 Mar-Apr;11(2):128-35. Epub 2008 Dec 6.PMID: 19067081 [PubMed - indexed for MEDLINE] - Contrast-enhanced microcomputed tomography using intraperitoneal contrast injection for the assessment of tumor-burden in liver metastasis models
Graham KC, Detombe SA, MacKenzie LT, Holdsworth DW, MacDonald IC, Chambers AF, Drangova M.
Invest Radiol. 2008 Jul;43(7):488-95.PMID: 18580331 [PubMed - indexed for MEDLINE] - Comparison of Fenestra VC Contrast-enhanced computed tomography imaging with gadopentetate dimeglumine and ferucarbotran magnetic resonance imaging for the in vivo evaluation of murine liver damage after ischemia and reperfusion
Choukèr A, Lizak M, Schimel D, Helmberger T, Ward JM, Despres D, Kaufmann I, Bruns C, Löhe F, Ohta A, Sitkovsky MV, Klaunberg B, Thiel M.
Invest Radiol. 2008 Feb;43(2):77-91.PMID: 18197060 [PubMed - indexed for MEDLINE] - MicroCT liver contrast agent enhancement over time, dose, and mouse strain
Suckow CE, Stout DB.
Mol Imaging Biol. 2008 Mar-Apr;10(2):114-20. Epub 2008 Jan 16.PMID: 18204990 [PubMed - indexed for MEDLINE] - Imaging characteristics of DHOG, a hepatobiliary contrast agent for preclinical microCT in mice
Henning T, Weber AW, Bauer JS, Meier R, Carlsen JM, Sutton EJ, Prevrhal S, Ziegler SI, Feussner H, Daldrup-Link HE, Rummeny EJ.
Acad Radiol. 2008 Mar;15(3):342-9.PMID: 18280932 [PubMed - indexed for MEDLINE] - In-vivo high-resolution X-ray microtomography for liver and spleen tumor assessment in mice
Almajdub M, Nejjari M, Poncet G, Magnier L, Chereul E, Roche C, Janier M.
Contrast Media Mol Imaging. 2007 Mar;2(2):88-93.PMID: 17444558 [PubMed - indexed for MEDLINE] - Time-course characterization of the computed tomography contrast enhancement of an iodinated blood-pool contrast agent in mice using a volumetric flat-panel equipped computed tomography scanner
Ford NL, Graham KC, Groom AC, Macdonald IC, Chambers AF, Holdsworth DW.
Invest Radiol. 2006 Apr;41(4):384-90.PMID: 16523021 [PubMed - indexed for MEDLINE]
Si vous voulez ajouter votre publication à cette liste de référence, contactez-nous à .
Imagerie multimodalité
PET/CT
- Quantitative PET reporter gene imaging of CD8+ T cells specific for a melanoma-expressed self-antigen
Shu CJ, Radu CG, Shelly SM, Vo DD, Prins R, Ribas A, Phelps ME, Witte ON.
Int Immunol. 2009 Feb;21(2):155-65. Epub 2008 Dec 23 - Tumor hypoxia imaging in orthotopic liver tumors and peritoneal metastasis: a comparative study featuring dynamic 18F-MISO and 124I-IAZG PET in the same study cohort
Riedl CC, Brader P, Zanzonico P, Reid V, Woo Y, Wen B, Ling CC, Hricak H, Fong Y, Humm JL.
Eur J Nucl Med Mol Imaging. 2008 Jan;35(1):39-46. Epub 2007 Sep 5 - A microPET/CT system for in vivo small animal imaging
Liang H, Yang Y, Yang K, Wu Y, Boone JM, Cherry SR.
Phys Med Biol. 2007 Jul 7;52(13):3881-94. Epub 2007 Jun 4 - Imaging hypoxia in orthotopic rat liver tumors with iodine 124-labeled iodoazomycin galactopyranoside PET
Riedl CC, Brader P, Zanzonico PB, Chun YS, Woo Y, Singh P, Carlin S, Wen B, Ling CC, Hricak H, Fong Y.
Radiology. 2008 Aug;248(2):561-70
SPECT/CT
- Noninvasive imaging of atherosclerotic lesions in apolipoprotein E-deficient and low-density-lipoprotein receptor-deficient mice with annexin A5
Isobe S, Tsimikas S, Zhou J, Fujimoto S, Sarai M, Branks MJ, Fujimoto A, Hofstra L, Reutelingsperger CP, Murohara T, Virmani R, Kolodgie FD, Narula N, Petrov A, Narula J.
J Nucl Med. 2006 Sep;47(9):1497-505 - Radioimaging of light chain amyloid with a fibril-reactive monoclonal antibody
Wall JS, Kennel SJ, Paulus M, Gregor J, Richey T, Avenell J, Yap J, Townsend D, Weiss DT, Solomon A.
J Nucl Med. 2006 Dec;47(12):2016-24.PMID: 17138745 [PubMed - indexed for MEDLINE]
Si vous voulez ajouter votre publication à cette liste de référence, contactez-nous à .
